ความรู้เรื่องเครื่องทำน้ำเย็น

This category will let you know about what can we do and how to make it via using our water chiller to change your life! Let’s share the latest technological information.

การเปรียบเทียบระหว่างวาล์วขยายตัวแบบอิเล็กทรอนิกส์และวาล์วขยายตัวทางความร้อน

การเปรียบเทียบระหว่างวาล์วขยายตัวแบบอิเล็กทรอนิกส์และวาล์วขยายตัวทางความร้อน

Now more and more civil and commercial refrigeration equipment use electronic expansion valve to replace the original thermal expansion valve. The electronic expansion valve and the thermal expansion valve have the same basic use, but different in performance.

1. Adjustment range

At present, the regulating range of thermal expansion valve is generally narrow. The heat pump unit should not only refrigeration, but also heating, and the ambient temperature range of the suitable occasions is from15 ℃ to + 43 ℃, and the corresponding refrigerant evaporation temperature will work in the range of25 ℃5 ℃. In addition, if there are multiple compressors in the refrigeration circuit, the number of compressors in operation will change accordingly with the change of user load, resulting in dramatic change of refrigerant flow.

Therefore, a single thermal expansion valve is far from competent for the operation of large heat pump units. At present, many large-scale heat pump products are designed with single loop and single compressor, and the expansion valve system with independent refrigeration mode and heating mode is adopted, which will increase the complexity and manufacturing cost of the system. The electronic expansion valve can be adjusted accurately in the range of 15% ~ 100%.

According to the current use effect, a single electronic expansion valve can meet the regulation of heat pump unit under the above conditions. The adjustable range can be set according to the characteristics of different products, which increases the flexibility.

2. Control of superheat

(1) Superheat control point:

For the thermal expansion valve, generally only the superheat at the evaporator outlet can be controlled. In the semi closed and fully closed compressor system, the control point can be set not only at the evaporator outlet, but also at the compressor suction port, which can control the suction superheat of the compressor to ensure the efficiency of the compressor.

(2) Superheat setting value:

For thermal expansion valve, its superheat setting value is generally set by the manufacturer in the manufacturing process, usually 5 ℃, 6 ℃ or 8 ℃. The superheat degree of the electronic expansion valve can be set manually according to the different characteristics of the product. For example, the superheat of the evaporator outlet is set to 6 ℃, and the superheat of the compressor suction can be set to 15 ℃, which is very flexible.

(3) Stability of superheat control under non-standard operating conditions:

The superheat setting values of thermal expansion valve are all set under standard conditions. However, due to the characteristics of charging working fluid, when the system deviates from the standard working condition, the superheat will deviate from the set value with the change of condensation pressure, which will not only cause the decrease of system efficiency, but also cause the fluctuation of the system. The superheat degree of the electronic expansion valve is set by the controller artificially, and the actual superheat degree of the system is calculated by the parameters of the control point collected by the sensor, so there is no such problem.

(4) Intelligence of system regulation:

The superheat control of thermal expansion valve is based on the state of the current control point, which is determined by the characteristics of working fluid filled. It can not judge the change trend of the system. The control logic of the electronic expansion valve can adopt various intelligent control systems according to the design and manufacturing characteristics of different products. It can not only adjust the current state of the system, but also distinguish the characteristics of the system according to the change rate of superheat degree and other parameters. The corresponding control methods are adopted for different system change trends. Therefore, its response speed and pertinence to system changes are superior to thermal expansion valve.

3. Reaction rate

The thermal expansion valve is driven by taking advantage of the thermal characteristics of the filling working medium, so its opening and closing characteristics are as follows:

(1) The sensitivity of reaction and the speed of opening and closing are slow.

(2) Generally speaking, the opening and closing speed of thermal expansion valve is relatively consistent.

(3) In the process of unit start-up, there is static superheat. The superheat (SH) of thermal expansion valve is composed of static superheat (SS) and opening superheat (OS). Due to the existence of static superheat, there will be a tendency to delay the opening of thermal expansion valve during startup.

The driving mode of the electronic expansion valve is that the controller calculates the parameters collected by the sensor, sends the regulation command to the driving board, and the driving board outputs the electric signal to the electronic expansion valve to drive the action of the electronic expansion valve. It takes only a few seconds for the electronic expansion valve to change from fully closed to fully open. It has fast reaction and action speed, and there is no static superheat phenomenon. Moreover, the opening and closing characteristics and speed can be set manually, which is especially suitable for the use of heat pump units with severe fluctuation of working conditions.

4. Diversity of control functions

In order to prevent compressor overload caused by excessive refrigerant pressure and flow at evaporation side during the initial start-up of the unit, the thermal expansion valve is generally equipped with mop function, that is, the expansion valve can only be opened when the evaporation pressure is lower than the set value. However, compared with the electronic expansion valve, its function is still monotonous.

The structure of the electronic expansion valve can be regarded as the organic combination of throttle mechanism and solenoid valve, and it can be adjusted by the controller. Therefore, according to different product characteristics, it shows the diversity and superiority of its control function under the conditions of unit start-up, load change, defrosting, shutdown and fault protection. For example: the electronic expansion valve to regulate the refrigerant flow can not only control the evaporator, but also can be used to adjust the condenser.

When the evaporation condition allows, if the condensation pressure is too high, the expansion valve can be properly closed to reduce the refrigerant flow in the system and the condenser load, so as to reduce the condensation pressure and realize the efficient and reliable operation of the unit.

การเปรียบเทียบระหว่างวาล์วขยายตัวแบบอิเล็กทรอนิกส์และวาล์วขยายตัวทางความร้อน Read More »

ลำดับการทำงานของเครื่องทำน้ำเย็น

ลำดับการทำงานของเครื่องทำน้ำเย็น

1.ตรวจสอบรายการก่อนที่จะป้อนข้อมูลพลังงาน

เมื่อแหล่งจ่ายไฟและน้ำประปาตรงตามข้อกำหนด จากนั้นเราสามารถป้อนพลังงานได้:ขั้นแรก ให้กดปุ่มเปิด/ปิดเครื่อง และตรวจสอบ:

1 ระดับของเหลวและเปิดวาล์วปั๊ม:

ระดับของเหลวของถังน้ำเย็นเป็นไปตามข้อกำหนดหรือไม่ และวาล์วด้านหน้าและด้านหลังของปั๊มน้ำเย็นเปิดอยู่หรือไม่

2) เปิดอ่างเก็บน้ำและปั้มน้ำ

เปิดสวิตช์หอทำความเย็นและปั๊มน้ำหล่อเย็น และให้ความสนใจกับการเปิดวาล์วทางเข้าและทางออกของน้ำหล่อเย็น (หมายเหตุ: ชนิดระบายความร้อนด้วยอากาศไม่จำเป็นต้องมีหอระบายความร้อน)

3 ตรวจสอบทิศทางการหมุน

เมื่อตรงตามเงื่อนไขข้างต้นทั้งหมด คุณสามารถใช้โหมดนิ้วเพื่อทดสอบว่าทิศทางของปั๊มน้ำหล่อเย็น ปั๊มน้ำเย็น พัดลมหอทำความเย็น และพัดลมควบแน่นของชุดระบายความร้อนด้วยอากาศนั้นถูกต้องหรือไม่ และการส่งผ่านน้ำและการดูดอากาศและ การปลดปล่อยเป็นเรื่องปกติ ถ้าไม่เช่นนั้นก็ต้องกำจัดทิ้งเสียก่อน

2. กดปุ่มเปิดเครื่องทำความเย็นแล้วปล่อยให้เครื่องทำงาน

เปิดสวิตช์การทำงานของเครื่องทำความเย็นอีกครั้ง จากนั้นปั๊มน้ำเย็นจะเริ่มทำงาน โปรดทราบว่าจะต้องเปิดวาล์วทางเข้าและทางออกของน้ำเย็น และคอมเพรสเซอร์จะทำงานโดยอัตโนมัติหลังจากสวิตช์หน่วงเวลา โปรดตรวจสอบและปรับอุณหภูมิที่ต้องการ

3. ความแตกต่างลำดับการเริ่มต้นของเครื่องทำความเย็นแบบระบายความร้อนด้วยน้ำและแบบระบายความร้อนด้วยอากาศ:

1 เครื่องทำความเย็นแบบระบายความร้อนด้วยน้ำ:

เปิดพัดลมคูลลิ่งทาวเวอร์และปั๊มน้ำหล่อเย็นก่อน จากนั้นจึงเปิดเครื่องทำความเย็น

2 เครื่องทำความเย็นแบบระบายความร้อนด้วยอากาศ:

สามารถเริ่มต้นได้โดยตรง

4. ลำดับการปิดเครื่อง:

1. หน่วยระบายความร้อนด้วยน้ำ:

ปิดเครื่องทำความเย็นก่อน จากนั้นจึงปิดพัดลมคูลลิ่งทาวเวอร์และปั๊มน้ำหล่อเย็น

2 หน่วยระบายความร้อนด้วยอากาศ:

สามารถปิดเครื่องได้โดยตรง

ลำดับการทำงานของเครื่องทำน้ำเย็น Read More »

Industrial Water chiller installation

ข้อกำหนดการติดตั้งเครื่องทำน้ำเย็นอุตสาหกรรม

Installation Requirements of Industrial Water Chiller

All the Installation requirements of industrial water chiller you should notice to make sure the chilling unit can run as long as it can.

Industrial chillers can be divided into two categories according to the heat dissipation mode: 1. Water cooling units; 2. Air cooling units.

The water-cooled unit must be connected with the cooling tower and the inlet and outlet pipes of cooling water and chilled water. The cooling tower and cooling pump should be selected according to the refrigeration capacity and compression power, with the inlet pressure ≥ 1.5bar, and the diameter of the inlet and outlet pipe should be consistent with the diameter of the cooling water inlet and outlet pipe.

However, the air-cooled unit only needs to connect the chilled water inlet and outlet pipes and make-up water source. After the power supply is connected, the operation can be carried out. The ventilation should be smooth, and there should be no dust and debris around to avoid being inhaled into the unit.

1.The diameter of the water pipe

The diameter of the water pipe connection port reserved by the unit is standard size. When the remote transmission is adopted, a larger diameter water pipe must be used for connection. In any case, the diameter of the water pipe should not be smaller than the standard diameter of the connection port, otherwise, the pressure alarm will be given and the compressor and water pump will be damaged greatly.

2.Connecting The Water Pipe

When connecting the water pipe, the user should refer to the installation diagram to connect the pipeline, confirm the position of the inlet and outlet pipe, distinguish the cooling water pipe and the chilled water pipe.The wrong connection of the pipe will damage the unit.Only after ensuring the normal connection of the whole system can the system be started up and run.

3.With Connector or Flange

When the water pipe is connected to the unit, it must be connected with a connector or flange, so that it can be easily removed when necessary.

4.Connect a Hose

A section of hose is connected to the outlet and inlet of the water pipe to reduce vibration transmission.

5.Valves and Filter

If permitted, install valves on water pipes to effectively control water flow. It is suggested to install a filter at the water inlet to prevent sediment and debris.

6.Check Leakage Problem

Check the internal and external have leakage problem or not,when the water inlet/outlet valve of evaporator and condenser is fully opened.

7.Wrap With Insulation Material

The water pipe should be wrapped with enough insulation cotton to protect it from frost on the surface and keep the chilling water temperature.

8.Winter Protection Measures

In winter, when the unit stops operation, the water in the water pump and water pipe may freeze, causing damage to the unit and water pipe. In order to prevent icing, when the unit stops, the water pump can be effectively started. If there is still possibility of icing, all water in the water pipe will be discharged. If drainage is difficult, an anti icing mixture such as ethylene glycol or propanol can be used.

9.By-pass Pipe

When installing the unit, please install the bypass pipe in the chilled water pipeline device. When the chilled water outlet valve is turned down, the bypass pipe valve can be adjusted to relieve the pump pressure and prevent the evaporator from freezing.

10.Check Before Running

When the air-cooled chiller is started up and running, please pay attention to whether the water pump and exhaust fan turn normally before starting up and running.

11.High/Low Pressure

When the unit is running, please pay attention to the pressure display content: water cooled high pressure is (1.2 ~ 1.8MPa), low pressure is (0.3 ~ 0.6MPa); air cooled high pressure is (1.2 ~ 1.9mpa), low pressure is (0.3 ~ 0.6MPa). If the value is too high or too low, it means that the fault is a precursor or improper use. Please check it in time or inform the manufacturer to deal with it. Maintenance in advance is better than repair afterwards.

12.Cooling Water and Scale

To ensure that the condenser is not easy to scale and can be used for a long time, please use softened water (or tap water) as cooling water. If a cooling tower is used, the cooling water should be replaced regularly.

13.Regular Cleanning

The condenser and evaporator of the chiller usually need to be cleaned after a period of use (the cleaning cycle depends on the surrounding environment and water quality).

14.Temperature Setting

It is better to control the outlet water temperature of the unit at 7 ~ 12 ℃. When adjusting the temperature controller, please note that low temperature will cause some protection devices of the unit to fail.

15.Electric Control Elements and Protection Devices

All electric control elements and protection devices of the unit have been strictly tested by the manufacturer. Users are not allowed to change or remove them during inspection and maintenance. Forced operation without protection will cause great damage to the unit.

ข้อกำหนดการติดตั้งเครื่องทำน้ำเย็นอุตสาหกรรม Read More »

ลักษณะและข้อดีของชิลเลอร์ประเภทต่างๆ

ลักษณะและข้อดีของ
เครื่องทำน้ำเย็นประเภทต่างๆ

1.

เครื่องทำน้ำเย็นชนิดกล่อง:

มีโครงสร้างที่กะทัดรัด มีถังเก็บน้ำและปั้มน้ำอยู่ภายใน เหมาะสำหรับอุปกรณ์ที่มีท่อภายนอกแบบปิด

รุ่นระบายความร้อนด้วยน้ำจะต้องติดตั้งปั๊มน้ำหล่อเย็นและหอทำความเย็นก่อนจึงจะสามารถใช้งานได้

2.

เครื่องทำความเย็นแบบระบายความร้อนด้วยอากาศแบบกล่อง:

นอกจากประสิทธิภาพทั้งหมดแบบกล่องแล้ว ยังไม่จำเป็นต้องเพิ่มปั๊มน้ำหล่อเย็นและหอหล่อเย็นอีกด้วย

มันง่ายในการติดตั้งและใช้งาน เหมาะสำหรับอุปกรณ์การผลิตขนาดเล็กที่มีความยืดหยุ่นและโรงงานที่ติดตั้งหอทำความเย็นโดยไม่มีเงื่อนไข

3.

เครื่องทำน้ำเย็นแบบเปิดระบายความร้อนด้วยน้ำ:

ไม่มีถังเก็บน้ำเย็นและปั้มน้ำแต่สามารถต่อกับปั้มน้ำและถังเก็บน้ำได้ตามต้องการ

ปริมาตรของถังเก็บน้ำและหัวปั๊มไม่จำกัด ซึ่งสามารถตอบสนองความต้องการของอุปกรณ์อุตสาหกรรมต่างๆ ได้ดียิ่งขึ้น

โครงสร้างแบบเปิด ทำความสะอาดง่ายและบำรุงรักษา

4.

ชิลเลอร์อุณหภูมิต่ำระบายความร้อนด้วยน้ำหรือระบายความร้อนด้วยอากาศ:

ควรใช้สารละลายป้องกันการแข็งตัว (เอทิลีนไกลคอลหรือน้ำเกลืออุณหภูมิต่ำ) เป็นสารทำความเย็นพาหะ และอุณหภูมิทางออกอาจต่ำกว่าศูนย์

ประกอบด้วยสามซีรี่ส์: อุณหภูมิสูง (อุณหภูมิน้ำออก: 3 ℃ – 5 ℃) อุณหภูมิปานกลาง (อุณหภูมิน้ำออก: – 5 ℃ – 10 ℃) และอุณหภูมิต่ำ (อุณหภูมิทางออกของน้ำ – 15 ℃) ซึ่งสามารถตอบสนองความต้องการอุณหภูมิต่ำของอุปกรณ์ต่าง ๆ และยังสามารถปรับแต่งตามความต้องการพิเศษของลูกค้า

5.

ประเภทสกรูระบายความร้อนด้วยน้ำ:

นำมาใช้กับคอนเดนเซอร์แบบเปลือกและท่อและคอนเดนเซอร์แบบเชลล์และท่อซึ่งมีลักษณะของโครงสร้างที่เรียบง่าย การแลกเปลี่ยนความร้อนที่เสถียร ประสิทธิภาพที่ยาวนาน และการบำรุงรักษาที่สะดวก

หน่วยนี้มีอุปกรณ์ป้องกันความปลอดภัยที่เชื่อถือได้ รวมถึง: ตัวป้องกันแรงดันไฟฟ้าสูงและต่ำ, ตัวป้องกันความร้อนเกินของไอเสีย, ตัวป้องกันมอเตอร์คอมเพรสเซอร์ร้อนเกินไป, ตัวป้องกันกระแสไฟเกิน, ตัวป้องกันอุณหภูมิแข็งตัว, ตัวป้องกันการไหลของน้ำ, สวิตช์หยุดฉุกเฉิน, สลักเกลียวหลอมที่ไวต่ออุณหภูมิ, วาล์วนิรภัย ฯลฯ .

เป็นที่ยอมรับกันว่า องค์ประกอบโครงสร้างที่เหมาะสมที่สุดของโฮสต์ทำความเย็นส่วนกลาง

6.

ประเภทท่อไทเทเนียมทนต่อการกัดกร่อน:

เครื่องระเหยไทเทเนียมแบบพิเศษสามารถหลีกเลี่ยงการกัดกร่อนของกรดของเหลว และสามารถแช่แข็งการชุบด้วยไฟฟ้า ของเหลวออกซิเดชัน น้ำทะเล น้ำเกลือ และของเหลวที่มีฤทธิ์กัดกร่อนอื่น ๆ ได้โดยตรง

ลักษณะและข้อดีของชิลเลอร์ประเภทต่างๆ Read More »

การเตรียมตัวก่อนติดตั้งเครื่องทำน้ำเย็น

Find it hard or complicate to install a water chiller? Don’t know how to pick up a right place to settle your new water chiller?

Actually , you just need to do below steps one by one.Then everything will become very simple.

Let’s do it!

Check the components are complete

Before installation, check whether the components of the unit are complete.

The Right Cooling water tower and Cooling water pump

Select the appropriate cooling tower (air cooling type does not need cooling tower), and the capacity of cooling water pump should match the model. Please install according to the size of the body pipe, do not reduce the size of the cooling pipe, in order to avoid causing high pressure overload, affecting the cooling effect and increasing power consumption.

Correct handling methods

Correct handling method: use stacker, crane and drum. Do not drag the machine by force. Since the equipment has been debugged before leaving the factory, the system has pressure, so strong vibration is not allowed during loading and unloading, handling and installation. It is not allowed to invert, tilt or side set the unit during handling.

The right installation location requested:

The water chiller is an indoor device. If the user needs to place the equipment outdoors, it should be well protected from rain and sun, and should not be directly exposed to the outside.

 

The installation location should be a place with stable foundation, open surroundings, ventilation, avoiding corrosion and pollution, and convenient for installation and maintenance.

Since the unit itself will generate heat, it is necessary to avoid high temperature area around the unit during installation to meet the effective heat dissipation of the equipment, especially to ensure that the condenser of air-cooled chiller is well ventilated.

Avoid placing high-power inverter, welding machine and other equipment with interference sources near the equipment, and the installation space of the unit shall not be less than the size shown in the figure below. The figure shows the minimum installation space of the unit (unit: mm).

Water-cooled water chiller (Box type or Open type)
Air-cooled water chiller

The unit without caster at the bottom

The unit without caster at the bottom must be placed on the horizontal concrete base, and there must be no less than 3mm thick damping rubber pad between the unit and the concrete base

It is better to install large air-cooled units in outdoor space-

On the other hand, it can reduce heat emission. When placing, please support the bottom of the unit with bracket to make it ventilate smoothly and prevent rusting.

Note:

(1) the power load and grounding part shall be constructed in accordance with relevant laws and regulations

(2) The chilled water pipes of newly installed chillers must be covered with insulation layer.

การเตรียมตัวก่อนติดตั้งเครื่องทำน้ำเย็น Read More »

การประยุกต์ใช้เครื่องทำความเย็นอุตสาหกรรม APT

การประยุกต์ใช้เทคโนโลยีเครื่องทำความเย็นในปี 2564

With the development of refrigeration industry, the application of refrigeration technology is becoming more and more extensive. Now it has penetrated into all fields of people’s life and production activities, from daily clothing, food, housing, transportation, to cutting-edge science and technology can not do without refrigeration technology.

1. Food Engineering

 

In order to prolong and improve the quality, economic life and value of perishable food, it is necessary to maintain a stable low temperature environment in the whole circulation process of perishable food from purchase or fishing, processing, storage, transportation to sales. This requires a variety of refrigeration facilities, such as cold processing equipment, refrigerated warehouses, refrigerated transport vehicles or ships, refrigerated sales counters and so on.

 

2. Air conditioning engineering

Air conditioning engineering is a wide application field of refrigeration technology. The temperature, humidity and cleanliness of the environment are required to be controlled in different degrees in optical instruments, precision measuring tools, textile workshops and computer rooms; comfortable air conditioning systems are also required for public buildings such as gymnasiums, great halls, hotels and other public buildings, cars, airplanes, and large buses.

3. Mechanical and electronic industry

เครื่องทำความเย็นด้วยน้ำอุตสาหกรรมขนาด 20HP

 

Precision machine tool oil pressure system uses refrigeration to control the oil temperature, which can stabilize the oil film stiffness and make the machine work normally. Low temperature treatment of steel can improve the properties of steel, improve the hardness and strength of steel, and prolong the service life of workpiece. Multi channel communication, radar, satellite ground station and other electronic equipment also need to work in low temperature.

 

Swimming pool water chiller 1HP-3HP

Plasma, vaccines and some special drugs need to be preserved at low temperature. Low temperature anesthesia, low temperature surgery and cold compress cooling of patients with high fever also need refrigeration technology.

4. National defense industry and modern science

It is also necessary to simulate the performance