Comparison Between Electronic Expansion Valve and Thermal Expansion Valve

Comparison Between Electronic Expansion Valve and Thermal Expansion Valve

Now more and more civil and commercial refrigeration equipment use electronic expansion valve to replace the original thermal expansion valve. The electronic expansion valve and the thermal expansion valve have the same basic use, but different in performance.

1. Adjustment range

At present, the regulating range of thermal expansion valve is generally narrow. The heat pump unit should not only refrigeration, but also heating, and the ambient temperature range of the suitable occasions is from15 ℃ to + 43 ℃, and the corresponding refrigerant evaporation temperature will work in the range of25 ℃5 ℃. In addition, if there are multiple compressors in the refrigeration circuit, the number of compressors in operation will change accordingly with the change of user load, resulting in dramatic change of refrigerant flow.

Therefore, a single thermal expansion valve is far from competent for the operation of large heat pump units. At present, many large-scale heat pump products are designed with single loop and single compressor, and the expansion valve system with independent refrigeration mode and heating mode is adopted, which will increase the complexity and manufacturing cost of the system. The electronic expansion valve can be adjusted accurately in the range of 15% ~ 100%.

According to the current use effect, a single electronic expansion valve can meet the regulation of heat pump unit under the above conditions. The adjustable range can be set according to the characteristics of different products, which increases the flexibility.

2. Control of superheat

(1) Superheat control point:

For the thermal expansion valve, generally only the superheat at the evaporator outlet can be controlled. In the semi closed and fully closed compressor system, the control point can be set not only at the evaporator outlet, but also at the compressor suction port, which can control the suction superheat of the compressor to ensure the efficiency of the compressor.

(2) Superheat setting value:

For thermal expansion valve, its superheat setting value is generally set by the manufacturer in the manufacturing process, usually 5 ℃, 6 ℃ or 8 ℃. The superheat degree of the electronic expansion valve can be set manually according to the different characteristics of the product. For example, the superheat of the evaporator outlet is set to 6 ℃, and the superheat of the compressor suction can be set to 15 ℃, which is very flexible.

(3) Stability of superheat control under non-standard operating conditions:

The superheat setting values of thermal expansion valve are all set under standard conditions. However, due to the characteristics of charging working fluid, when the system deviates from the standard working condition, the superheat will deviate from the set value with the change of condensation pressure, which will not only cause the decrease of system efficiency, but also cause the fluctuation of the system. The superheat degree of the electronic expansion valve is set by the controller artificially, and the actual superheat degree of the system is calculated by the parameters of the control point collected by the sensor, so there is no such problem.

(4) Intelligence of system regulation:

The superheat control of thermal expansion valve is based on the state of the current control point, which is determined by the characteristics of working fluid filled. It can not judge the change trend of the system. The control logic of the electronic expansion valve can adopt various intelligent control systems according to the design and manufacturing characteristics of different products. It can not only adjust the current state of the system, but also distinguish the characteristics of the system according to the change rate of superheat degree and other parameters. The corresponding control methods are adopted for different system change trends. Therefore, its response speed and pertinence to system changes are superior to thermal expansion valve.

3. Reaction rate

The thermal expansion valve is driven by taking advantage of the thermal characteristics of the filling working medium, so its opening and closing characteristics are as follows:

(1) The sensitivity of reaction and the speed of opening and closing are slow.

(2) Generally speaking, the opening and closing speed of thermal expansion valve is relatively consistent.

(3) In the process of unit start-up, there is static superheat. The superheat (SH) of thermal expansion valve is composed of static superheat (SS) and opening superheat (OS). Due to the existence of static superheat, there will be a tendency to delay the opening of thermal expansion valve during startup.

The driving mode of the electronic expansion valve is that the controller calculates the parameters collected by the sensor, sends the regulation command to the driving board, and the driving board outputs the electric signal to the electronic expansion valve to drive the action of the electronic expansion valve. It takes only a few seconds for the electronic expansion valve to change from fully closed to fully open. It has fast reaction and action speed, and there is no static superheat phenomenon. Moreover, the opening and closing characteristics and speed can be set manually, which is especially suitable for the use of heat pump units with severe fluctuation of working conditions.

4. Diversity of control functions

In order to prevent compressor overload caused by excessive refrigerant pressure and flow at evaporation side during the initial start-up of the unit, the thermal expansion valve is generally equipped with mop function, that is, the expansion valve can only be opened when the evaporation pressure is lower than the set value. However, compared with the electronic expansion valve, its function is still monotonous.

The structure of the electronic expansion valve can be regarded as the organic combination of throttle mechanism and solenoid valve, and it can be adjusted by the controller. Therefore, according to different product characteristics, it shows the diversity and superiority of its control function under the conditions of unit start-up, load change, defrosting, shutdown and fault protection. For example: the electronic expansion valve to regulate the refrigerant flow can not only control the evaporator, but also can be used to adjust the condenser.

When the evaporation condition allows, if the condensation pressure is too high, the expansion valve can be properly closed to reduce the refrigerant flow in the system and the condenser load, so as to reduce the condensation pressure and realize the efficient and reliable operation of the unit.

Comparison Between Electronic Expansion Valve and Thermal Expansion Valve Read More »

Operation Sequence of Water Chiller

Operation Sequence of Water Chiller

1.CHECK LIST BEFORE INPUT POWER

WHEN the power supply and water supply both meet the requirements,then can we input the power:FIRST, press the power button ON, and check :

① LIQUID LEVEL AND OPEN THE PUMP VALVE:

Whether the liquid level of the cold water tank meets the requirements and whether the front and rear valves of the cold water pump have been opened;

② OPEN THE WATER TOWER AND PUMP

Turn on the switch of cooling water tower and cooling water pump, and pay attention to the opening of inlet and outlet valves of cooling water. (Note: air cooled type does not need cooling water tower)

③CHECK THE TURNING DIRECTION

When all the above conditions are met, you can use the inching mode to test whether the direction of cooling water pump, cold water pump, cooling tower fan and condensing fan of air cooling unit is correct, and whether the water transmission and air suction and discharge are normal. If not, they must be eliminated first.

2. PRESS THE CHILLER OPEN BUTTON AND LET IT RUN

Turn on the running switch of the chiller again, and the chilled water pump starts to run. Please note that the inlet and outlet valves of the chilled water must be opened, and the compressor will run automatically after the delay switch. Please check and adjust the required temperature.

3. Startup sequence difference of water-cooled and air-cooled chiller:

① Water cooled chiller unit:

turn on the cooling tower fan and cooling water pump first, and then turn on the chiller

② Air cooled chiller unit:

can be started directly

4. Shutdown sequence:

① Water cooled unit:

turn off the chiller first, then turn off the cooling tower fan and cooling water pump

② Air cooled unit:

It can be shut down directly.

Operation Sequence of Water Chiller Read More »

Industrial Water chiller installation

Endüstriyel su soğutucunun kurulum gereksinimleri

Installation Requirements of Industrial Water Chiller

All the Installation requirements of industrial water chiller you should notice to make sure the chilling unit can run as long as it can.

Industrial chillers can be divided into two categories according to the heat dissipation mode: 1. Water cooling units; 2. Air cooling units.

The water-cooled unit must be connected with the cooling tower and the inlet and outlet pipes of cooling water and chilled water. The cooling tower and cooling pump should be selected according to the refrigeration capacity and compression power, with the inlet pressure ≥ 1.5bar, and the diameter of the inlet and outlet pipe should be consistent with the diameter of the cooling water inlet and outlet pipe.

However, the air-cooled unit only needs to connect the chilled water inlet and outlet pipes and make-up water source. After the power supply is connected, the operation can be carried out. The ventilation should be smooth, and there should be no dust and debris around to avoid being inhaled into the unit.

1.The diameter of the water pipe

The diameter of the water pipe connection port reserved by the unit is standard size. When the remote transmission is adopted, a larger diameter water pipe must be used for connection. In any case, the diameter of the water pipe should not be smaller than the standard diameter of the connection port, otherwise, the pressure alarm will be given and the compressor and water pump will be damaged greatly.

2.Connecting The Water Pipe

When connecting the water pipe, the user should refer to the installation diagram to connect the pipeline, confirm the position of the inlet and outlet pipe, distinguish the cooling water pipe and the chilled water pipe.The wrong connection of the pipe will damage the unit.Only after ensuring the normal connection of the whole system can the system be started up and run.

3.With Connector or Flange

When the water pipe is connected to the unit, it must be connected with a connector or flange, so that it can be easily removed when necessary.

4.Connect a Hose

A section of hose is connected to the outlet and inlet of the water pipe to reduce vibration transmission.

5.Valves and Filter

If permitted, install valves on water pipes to effectively control water flow. It is suggested to install a filter at the water inlet to prevent sediment and debris.

6.Check Leakage Problem

Check the internal and external have leakage problem or not,when the water inlet/outlet valve of evaporator and condenser is fully opened.

7.Wrap With Insulation Material

The water pipe should be wrapped with enough insulation cotton to protect it from frost on the surface and keep the chilling water temperature.

8.Winter Protection Measures

In winter, when the unit stops operation, the water in the water pump and water pipe may freeze, causing damage to the unit and water pipe. In order to prevent icing, when the unit stops, the water pump can be effectively started. If there is still possibility of icing, all water in the water pipe will be discharged. If drainage is difficult, an anti icing mixture such as ethylene glycol or propanol can be used.

9.By-pass Pipe

When installing the unit, please install the bypass pipe in the chilled water pipeline device. When the chilled water outlet valve is turned down, the bypass pipe valve can be adjusted to relieve the pump pressure and prevent the evaporator from freezing.

10.Check Before Running

When the air-cooled chiller is started up and running, please pay attention to whether the water pump and exhaust fan turn normally before starting up and running.

11.High/Low Pressure

When the unit is running, please pay attention to the pressure display content: water cooled high pressure is (1.2 ~ 1.8MPa), low pressure is (0.3 ~ 0.6MPa); air cooled high pressure is (1.2 ~ 1.9mpa), low pressure is (0.3 ~ 0.6MPa). If the value is too high or too low, it means that the fault is a precursor or improper use. Please check it in time or inform the manufacturer to deal with it. Maintenance in advance is better than repair afterwards.

12.Cooling Water and Scale

To ensure that the condenser is not easy to scale and can be used for a long time, please use softened water (or tap water) as cooling water. If a cooling tower is used, the cooling water should be replaced regularly.

13.Regular Cleanning

The condenser and evaporator of the chiller usually need to be cleaned after a period of use (the cleaning cycle depends on the surrounding environment and water quality).

14.Temperature Setting

It is better to control the outlet water temperature of the unit at 7 ~ 12 ℃. When adjusting the temperature controller, please note that low temperature will cause some protection devices of the unit to fail.

15.Electric Control Elements and Protection Devices

All electric control elements and protection devices of the unit have been strictly tested by the manufacturer. Users are not allowed to change or remove them during inspection and maintenance. Forced operation without protection will cause great damage to the unit.

Endüstriyel su soğutucunun kurulum gereksinimleri Read More »

Farklı tipteki soğutucuların özellikleri ve avantajları

Özellikleri ve avantajları
farklı türleri Su Soğutucular

1.

Kutu tipi su soğutmalı soğutucu:

İçerisinde su deposu ve su pompası bulunan kompakt bir yapıya sahiptir. Kapalı harici boru hattına sahip ekipmanlar için uygundur.

Su soğutmalı modelin kullanıma sunulabilmesi için soğutma suyu pompası ve soğutma kulesi ile donatılması gerekmektedir.

2.

Kutu tipi hava soğutmalı soğutma grubu:

Kutu tipinin tüm performansının yanı sıra soğutma suyu pompası ve soğutma kulesi ilavesine gerek yoktur.

Kurulumu ve çalıştırılması kolaydır. Küçük esnek üretim ekipmanları ve soğutma kulesinin koşulsuz olarak monte edildiği atölyeler için uygundur.

3.

Su soğutmalı açık tip su soğutucu:

Soğutulmuş su deposu ve su pompası ile donatılmamıştır ancak gerektiğinde su pompası ve su deposuna bağlanabilir.

Su deposu ve pompa kafasının hacmi sınırlı değildir, bu da farklı endüstriyel ekipmanların ihtiyaçlarını daha iyi karşılayabilir.

Açık yapı, temizlenmesi ve bakımı kolaydır.

4.

Su soğutmalı veya hava soğutmalı düşük sıcaklıklı soğutma grupları:

Taşıyıcı soğutucu olarak antifriz çözeltisi (etilen glikol veya düşük sıcaklıktaki tuzlu su) kullanılmalı ve çıkış sıcaklığı sıfırın altında olabilir.

Üç seri içerir: yüksek sıcaklık (su çıkış sıcaklığı: 3 OC – 5 °C), orta sıcaklık (su çıkış sıcaklığı: – 5°C – 10°C) ve düşük sıcaklık (su çıkış sıcaklığı) – Çeşitli ekipmanların düşük sıcaklık gereksinimlerini karşılayabilen ve ayrıca müşterilerin özel gereksinimlerine göre özelleştirilebilen.

5.

Su soğutmalı vida tipi:

Basit yapı, istikrarlı ısı değişimi, uzun ömürlü verimlilik ve uygun bakım özelliklerine sahip kabuk ve borulu kondansatör ve kabuk ve borulu kondenser ile benimsenmiştir.

Ünite, aşağıdakileri içeren güvenilir güvenlik koruma cihazlarına sahiptir: yüksek ve alçak gerilim koruyucusu, egzoz aşırı ısınma koruyucusu, kompresör motoru aşırı ısınma koruyucusu, aşırı yük akımı koruyucusu, antifriz sıcaklık koruyucusu, su akış koruyucusu, acil durdurma anahtarı, sıcaklığa duyarlı eriyebilir cıvata, emniyet valfi vb. .

Olarak tanınır Merkezi soğutma konağının en ideal yapı bileşimi.

6.

Korozyona dayanıklı titanyum tüp tipi:

Özel titanyum buharlaştırıcı, asit sıvı korozyonunu önleyebilir ve elektrokaplama, oksidasyon sıvısı, deniz suyu, tuzlu su ve diğer aşındırıcı sıvıları doğrudan dondurabilir.

Farklı tipteki soğutucuların özellikleri ve avantajları Read More »

Su Soğutucu Kurulumundan Önce Hazırlık

Su soğutucunun kurulumunu zor veya karmaşık mı buluyorsunuz? Yeni su soğutucunuzu yerleştirmek için doğru yeri nasıl seçeceğinizi bilmiyor musunuz?

Aslında aşağıdaki adımları tek tek yapmanız yeterli. O zaman her şey çok basitleşecek.

Hadi yapalım!

Bileşenlerin eksiksiz olup olmadığını kontrol edin

ÖnceKurulumu yeniden yaparken ünite bileşenlerinin eksiksiz olup olmadığını kontrol edin.

Doğru Soğutma suyu kulesi ve Soğutma suyu pompası

Uygun soğutma kulesini seçin (hava soğutma tipi soğutma kulesine ihtiyaç duymaz) ve soğutma suyu pompasının kapasitesi modele uygun olmalıdır. Lütfen gövde borusunun boyutuna göre kurulum yapın, yüksek basınç aşırı yüklenmesine neden olmaktan, soğutma etkisini etkilemekten ve güç tüketimini arttırmaktan kaçınmak için soğutma borusunun boyutunu azaltmayın.

Doğru kullanım yöntemleri

Doğru taşıma yöntemi: istifleyici, vinç ve tambur kullanın. Makineyi zorla sürüklemeyin. Ekipman fabrikadan çıkmadan önce hata ayıklaması yapıldığından, sistemde basınç vardır, bu nedenle yükleme ve boşaltma, taşıma ve kurulum sırasında güçlü titreşime izin verilmez. Taşıma sırasında ünitenin ters çevrilmesine, eğilmesine veya yana ayarlanmasına izin verilmez.

İstenen doğru kurulum konumu:

Su soğutucu bir iç mekan cihazı. Kullanıcının ekipmanı dış mekana yerleştirmesi gerekiyorsa, iyi durumda olmalıdır. yağmur ve güneşten korunmalı, dışarıya doğrudan maruz bırakılmamalıdır.

 

Kurulum yeri şu şekilde olmalıdır: Temeli sağlam, çevresi açık, havalandırmalı, korozyon ve kirlenmeyi önleyen, kurulum ve bakıma uygun bir yer.

Ünitenin kendisi ısı üreteceğinden, özellikle hava soğutmalı soğutma grubunun kondenserinin iyi havalandırılmasını sağlamak için ekipmanın etkili ısı dağılımını sağlamak amacıyla kurulum sırasında ünite çevresinde yüksek sıcaklıktaki alandan kaçınmak gerekir.

Yüksek güçlü invertör, kaynak makinesi ve parazit kaynağı olan diğer ekipmanı ekipmanın yakınına yerleştirmekten kaçının ve ünitenin kurulum alanı gösterilen boyuttan daha az olmamalıdır. aşağıdaki şekilde. Şekil ünitenin minimum montaj alanını göstermektedir (birim: mm).

Su soğutmalı su soğutma grubu (Kutu tip veya Açık tip)
Hava soğutmalı su soğutucu

Altta tekerleksiz ünite

Alt kısmında tekerlek bulunmayan ünite, yatay beton taban üzerine yerleştirilmeli ve ünite ile beton taban arasında en az 3 mm kalınlığında sönümleyici lastik ped bulunmalıdır.

Büyük hava soğutmalı ünitelerin dış mekana kurulması daha iyidir.

Öte yandan ısı emisyonunu da azaltabilir. Yerleştirirken, düzgün bir şekilde havalandırılması ve paslanmanın önlenmesi için lütfen ünitenin altını braket ile destekleyin.

Not:

(1) güç yükü ve topraklama kısmı İlgili yasa ve yönetmeliklere uygun olarak inşa edilecektir.

(2) Yeni kurulan soğutma gruplarının soğutulmuş su boruları yalıtım tabakası ile kaplanmalıdır.

Su Soğutucu Kurulumundan Önce Hazırlık Read More »

The Application of APT industry chillers

2021'de soğutma teknolojisinin uygulanması

With the development of refrigeration industry, the application of refrigeration technology is becoming more and more extensive. Now it has penetrated into all fields of people’s life and production activities, from daily clothing, food, housing, transportation, to cutting-edge science and technology can not do without refrigeration technology.

1. Food Engineering

 

In order to prolong and improve the quality, economic life and value of perishable food, it is necessary to maintain a stable low temperature environment in the whole circulation process of perishable food from purchase or fishing, processing, storage, transportation to sales. This requires a variety of refrigeration facilities, such as cold processing equipment, refrigerated warehouses, refrigerated transport vehicles or ships, refrigerated sales counters and so on.

 

2. Air conditioning engineering

Air conditioning engineering is a wide application field of refrigeration technology. The temperature, humidity and cleanliness of the environment are required to be controlled in different degrees in optical instruments, precision measuring tools, textile workshops and computer rooms; comfortable air conditioning systems are also required for public buildings such as gymnasiums, great halls, hotels and other public buildings, cars, airplanes, and large buses.

3. Mechanical and electronic industry

20HP endüstriyel su soğutmalı soğutucu

 

Precision machine tool oil pressure system uses refrigeration to control the oil temperature, which can stabilize the oil film stiffness and make the machine work normally. Low temperature treatment of steel can improve the properties of steel, improve the hardness and strength of steel, and prolong the service life of workpiece. Multi channel communication, radar, satellite ground station and other electronic equipment also need to work in low temperature.

 

Swimming pool water chiller 1HP-3HP

Plasma, vaccines and some special drugs need to be preserved at low temperature. Low temperature anesthesia, low temperature surgery and cold compress cooling of patients with high fever also need refrigeration technology.

4. National defense industry and modern science

It is also necessary to simulate the performance

of these weapons and vehicles in the cold environment. Artificial rainfall also needs cooling.

2021'de soğutma teknolojisinin uygulanması Read More »

Teşekkür ederim !

Mesaj başarılı bir şekilde gönderildi.

1 iş günü içinde sizinle iletişime geçeceğiz. “@topwaterchiller.com”.

Umarım gelecekte istikrarlı bir ssinlik ilişkimiz vardır.