So sánh giữa Van giãn nở điện tử và Van giãn nở nhiệt

So sánh giữa Van giãn nở điện tử và Van giãn nở nhiệt

Now more and more civil and commercial refrigeration equipment use electronic expansion valve to replace the original thermal expansion valve. The electronic expansion valve and the thermal expansion valve have the same basic use, but different in performance.

1. Adjustment range

At present, the regulating range of thermal expansion valve is generally narrow. The heat pump unit should not only refrigeration, but also heating, and the ambient temperature range of the suitable occasions is from15 ℃ to + 43 ℃, and the corresponding refrigerant evaporation temperature will work in the range of25 ℃5 ℃. In addition, if there are multiple compressors in the refrigeration circuit, the number of compressors in operation will change accordingly with the change of user load, resulting in dramatic change of refrigerant flow.

Therefore, a single thermal expansion valve is far from competent for the operation of large heat pump units. At present, many large-scale heat pump products are designed with single loop and single compressor, and the expansion valve system with independent refrigeration mode and heating mode is adopted, which will increase the complexity and manufacturing cost of the system. The electronic expansion valve can be adjusted accurately in the range of 15% ~ 100%.

According to the current use effect, a single electronic expansion valve can meet the regulation of heat pump unit under the above conditions. The adjustable range can be set according to the characteristics of different products, which increases the flexibility.

2. Control of superheat

(1) Superheat control point:

For the thermal expansion valve, generally only the superheat at the evaporator outlet can be controlled. In the semi closed and fully closed compressor system, the control point can be set not only at the evaporator outlet, but also at the compressor suction port, which can control the suction superheat of the compressor to ensure the efficiency of the compressor.

(2) Superheat setting value:

For thermal expansion valve, its superheat setting value is generally set by the manufacturer in the manufacturing process, usually 5 ℃, 6 ℃ or 8 ℃. The superheat degree of the electronic expansion valve can be set manually according to the different characteristics of the product. For example, the superheat of the evaporator outlet is set to 6 ℃, and the superheat of the compressor suction can be set to 15 ℃, which is very flexible.

(3) Stability of superheat control under non-standard operating conditions:

The superheat setting values of thermal expansion valve are all set under standard conditions. However, due to the characteristics of charging working fluid, when the system deviates from the standard working condition, the superheat will deviate from the set value with the change of condensation pressure, which will not only cause the decrease of system efficiency, but also cause the fluctuation of the system. The superheat degree of the electronic expansion valve is set by the controller artificially, and the actual superheat degree of the system is calculated by the parameters of the control point collected by the sensor, so there is no such problem.

(4) Intelligence of system regulation:

The superheat control of thermal expansion valve is based on the state of the current control point, which is determined by the characteristics of working fluid filled. It can not judge the change trend of the system. The control logic of the electronic expansion valve can adopt various intelligent control systems according to the design and manufacturing characteristics of different products. It can not only adjust the current state of the system, but also distinguish the characteristics of the system according to the change rate of superheat degree and other parameters. The corresponding control methods are adopted for different system change trends. Therefore, its response speed and pertinence to system changes are superior to thermal expansion valve.

3. Reaction rate

The thermal expansion valve is driven by taking advantage of the thermal characteristics of the filling working medium, so its opening and closing characteristics are as follows:

(1) The sensitivity of reaction and the speed of opening and closing are slow.

(2) Generally speaking, the opening and closing speed of thermal expansion valve is relatively consistent.

(3) In the process of unit start-up, there is static superheat. The superheat (SH) of thermal expansion valve is composed of static superheat (SS) and opening superheat (OS). Due to the existence of static superheat, there will be a tendency to delay the opening of thermal expansion valve during startup.

The driving mode of the electronic expansion valve is that the controller calculates the parameters collected by the sensor, sends the regulation command to the driving board, and the driving board outputs the electric signal to the electronic expansion valve to drive the action of the electronic expansion valve. It takes only a few seconds for the electronic expansion valve to change from fully closed to fully open. It has fast reaction and action speed, and there is no static superheat phenomenon. Moreover, the opening and closing characteristics and speed can be set manually, which is especially suitable for the use of heat pump units with severe fluctuation of working conditions.

4. Diversity of control functions

In order to prevent compressor overload caused by excessive refrigerant pressure and flow at evaporation side during the initial start-up of the unit, the thermal expansion valve is generally equipped with mop function, that is, the expansion valve can only be opened when the evaporation pressure is lower than the set value. However, compared with the electronic expansion valve, its function is still monotonous.

The structure of the electronic expansion valve can be regarded as the organic combination of throttle mechanism and solenoid valve, and it can be adjusted by the controller. Therefore, according to different product characteristics, it shows the diversity and superiority of its control function under the conditions of unit start-up, load change, defrosting, shutdown and fault protection. For example: the electronic expansion valve to regulate the refrigerant flow can not only control the evaporator, but also can be used to adjust the condenser.

When the evaporation condition allows, if the condensation pressure is too high, the expansion valve can be properly closed to reduce the refrigerant flow in the system and the condenser load, so as to reduce the condensation pressure and realize the efficient and reliable operation of the unit.

So sánh giữa Van giãn nở điện tử và Van giãn nở nhiệt Đọc thêm »

Trình tự vận hành máy làm lạnh nước

Trình tự vận hành máy làm lạnh nước

1. DANH SÁCH KIỂM TRA TRƯỚC KHI ĐIỆN VÀO

KHI cả nguồn điện và nguồn nước đều đáp ứng yêu cầu thì chúng ta có thể nhập nguồn: ĐẦU TIÊN, nhấn nút nguồn BẬT và kiểm tra:

① MỨC CHẤT LỎNG VÀ MỞ VAN BƠM:

Mức chất lỏng của bể nước lạnh có đáp ứng yêu cầu hay không và van trước và sau của bơm nước lạnh đã được mở hay chưa;

② MỞ THÁP NƯỚC VÀ BƠM NƯỚC

Bật công tắc của tháp nước làm mát và bơm nước làm mát, đồng thời chú ý đến việc mở van đầu vào và đầu ra của nước làm mát. (Lưu ý: loại làm mát bằng gió không cần tháp nước giải nhiệt)

③KIỂM TRA HƯỚNG QUAY

Khi đáp ứng tất cả các điều kiện trên, bạn có thể sử dụng chế độ nhích để kiểm tra xem hướng bơm nước làm mát, bơm nước lạnh, quạt tháp giải nhiệt và quạt ngưng tụ của bộ làm mát không khí có chính xác hay không và liệu truyền nước và hút không khí và xả là bình thường. Nếu không, chúng phải bị loại bỏ trước tiên.

2. NHẤN NÚT MỞ MÁY LÀM LẠNH VÀ ĐỂ NÓ CHẠY

Bật lại công tắc chạy của máy làm lạnh và máy bơm nước lạnh bắt đầu chạy. Xin lưu ý rằng van đầu vào và đầu ra của nước lạnh phải được mở và máy nén sẽ tự động chạy sau công tắc trễ. Vui lòng kiểm tra và điều chỉnh nhiệt độ cần thiết.

3. Sự khác biệt về trình tự khởi động của chiller giải nhiệt bằng nước và giải nhiệt bằng không khí:

① Bộ làm lạnh làm mát bằng nước:

bật quạt tháp giải nhiệt và bơm nước làm mát trước, sau đó bật máy làm lạnh

② Bộ làm lạnh làm mát bằng không khí:

có thể được bắt đầu trực tiếp

4. Trình tự tắt máy:

① Bộ phận làm mát bằng nước:

tắt máy làm lạnh trước, sau đó tắt quạt tháp giải nhiệt và bơm nước làm mát

② Bộ làm mát bằng không khí:

Nó có thể được tắt trực tiếp.

Trình tự vận hành máy làm lạnh nước Đọc thêm »

Industrial Water chiller installation

Yêu cầu lắp đặt máy làm lạnh nước công nghiệp

Installation Requirements of Industrial Water Chiller

All the Installation requirements of industrial water chiller you should notice to make sure the chilling unit can run as long as it can.

Industrial chillers can be divided into two categories according to the heat dissipation mode: 1. Water cooling units; 2. Air cooling units.

The water-cooled unit must be connected with the cooling tower and the inlet and outlet pipes of cooling water and chilled water. The cooling tower and cooling pump should be selected according to the refrigeration capacity and compression power, with the inlet pressure ≥ 1.5bar, and the diameter of the inlet and outlet pipe should be consistent with the diameter of the cooling water inlet and outlet pipe.

However, the air-cooled unit only needs to connect the chilled water inlet and outlet pipes and make-up water source. After the power supply is connected, the operation can be carried out. The ventilation should be smooth, and there should be no dust and debris around to avoid being inhaled into the unit.

1.The diameter of the water pipe

The diameter of the water pipe connection port reserved by the unit is standard size. When the remote transmission is adopted, a larger diameter water pipe must be used for connection. In any case, the diameter of the water pipe should not be smaller than the standard diameter of the connection port, otherwise, the pressure alarm will be given and the compressor and water pump will be damaged greatly.

2.Connecting The Water Pipe

When connecting the water pipe, the user should refer to the installation diagram to connect the pipeline, confirm the position of the inlet and outlet pipe, distinguish the cooling water pipe and the chilled water pipe.The wrong connection of the pipe will damage the unit.Only after ensuring the normal connection of the whole system can the system be started up and run.

3.With Connector or Flange

When the water pipe is connected to the unit, it must be connected with a connector or flange, so that it can be easily removed when necessary.

4.Connect a Hose

A section of hose is connected to the outlet and inlet of the water pipe to reduce vibration transmission.

5.Valves and Filter

If permitted, install valves on water pipes to effectively control water flow. It is suggested to install a filter at the water inlet to prevent sediment and debris.

6.Check Leakage Problem

Check the internal and external have leakage problem or not,when the water inlet/outlet valve of evaporator and condenser is fully opened.

7.Wrap With Insulation Material

The water pipe should be wrapped with enough insulation cotton to protect it from frost on the surface and keep the chilling water temperature.

8.Winter Protection Measures

In winter, when the unit stops operation, the water in the water pump and water pipe may freeze, causing damage to the unit and water pipe. In order to prevent icing, when the unit stops, the water pump can be effectively started. If there is still possibility of icing, all water in the water pipe will be discharged. If drainage is difficult, an anti icing mixture such as ethylene glycol or propanol can be used.

9.By-pass Pipe

When installing the unit, please install the bypass pipe in the chilled water pipeline device. When the chilled water outlet valve is turned down, the bypass pipe valve can be adjusted to relieve the pump pressure and prevent the evaporator from freezing.

10.Check Before Running

When the air-cooled chiller is started up and running, please pay attention to whether the water pump and exhaust fan turn normally before starting up and running.

11.High/Low Pressure

When the unit is running, please pay attention to the pressure display content: water cooled high pressure is (1.2 ~ 1.8MPa), low pressure is (0.3 ~ 0.6MPa); air cooled high pressure is (1.2 ~ 1.9mpa), low pressure is (0.3 ~ 0.6MPa). If the value is too high or too low, it means that the fault is a precursor or improper use. Please check it in time or inform the manufacturer to deal with it. Maintenance in advance is better than repair afterwards.

12.Cooling Water and Scale

To ensure that the condenser is not easy to scale and can be used for a long time, please use softened water (or tap water) as cooling water. If a cooling tower is used, the cooling water should be replaced regularly.

13.Regular Cleanning

The condenser and evaporator of the chiller usually need to be cleaned after a period of use (the cleaning cycle depends on the surrounding environment and water quality).

14.Temperature Setting

It is better to control the outlet water temperature of the unit at 7 ~ 12 ℃. When adjusting the temperature controller, please note that low temperature will cause some protection devices of the unit to fail.

15.Electric Control Elements and Protection Devices

All electric control elements and protection devices of the unit have been strictly tested by the manufacturer. Users are not allowed to change or remove them during inspection and maintenance. Forced operation without protection will cause great damage to the unit.

Yêu cầu lắp đặt máy làm lạnh nước công nghiệp Đọc thêm »

Đặc điểm và ưu điểm của các loại máy làm lạnh

Đặc điểm và ưu điểm của
các loại Máy làm lạnh nước

1.

Máy làm lạnh nước dạng hộp:

Nó có cấu trúc nhỏ gọn, có bình chứa nước và máy bơm nước bên trong. Nó phù hợp cho các thiết bị có đường ống bên ngoài kín.

Model làm mát bằng nước cần được trang bị bơm nước làm mát và tháp giải nhiệt trước khi đưa vào sử dụng.

2.

Máy làm lạnh làm mát bằng không khí kiểu hộp:

Ngoài tất cả công năng của loại hộp, không cần thêm bơm nước làm mát và tháp giải nhiệt.

Nó rất dễ dàng để cài đặt và vận hành. Nó phù hợp cho các thiết bị và xưởng sản xuất linh hoạt nhỏ, nơi lắp đặt tháp giải nhiệt vô điều kiện.

3.

Máy làm lạnh nước loại mở làm mát bằng nước:

Nó không được trang bị bể chứa nước lạnh và máy bơm nước, nhưng có thể kết nối với máy bơm nước và bể chứa nước theo yêu cầu.

Thể tích bể chứa nước và đầu bơm không bị giới hạn, có thể đáp ứng tốt hơn nhu cầu của các thiết bị công nghiệp khác nhau.

Cấu trúc mở, dễ dàng vệ sinh và bảo trì.

4.

Máy làm lạnh nhiệt độ thấp làm mát bằng nước hoặc làm mát bằng không khí:

Nên sử dụng dung dịch chống đông (ethylene glycol hoặc nước muối nhiệt độ thấp) làm chất làm lạnh mang và nhiệt độ đầu ra có thể dưới 0.

Nó bao gồm ba loạt: nhiệt độ cao (nhiệt độ đầu ra nước: 3oC – 5oC), nhiệt độ trung bình (nhiệt độ đầu ra nước: – 5oC – 10oC) và nhiệt độ thấp (nhiệt độ đầu ra nước – 15oC), có thể đáp ứng các yêu cầu nhiệt độ thấp của nhiều thiết bị khác nhau và cũng có thể được tùy chỉnh theo yêu cầu đặc biệt của khách hàng.

5.

Loại trục vít làm mát bằng nước:

Được sử dụng với thiết bị ngưng tụ vỏ và ống và thiết bị ngưng tụ vỏ và ống, có đặc điểm cấu trúc đơn giản, trao đổi nhiệt ổn định, hiệu quả lâu dài và bảo trì thuận tiện.

Thiết bị có các thiết bị bảo vệ an toàn đáng tin cậy, bao gồm: bộ bảo vệ điện áp cao và thấp, bộ bảo vệ quá nhiệt khí thải, bộ bảo vệ quá nhiệt động cơ máy nén, bộ bảo vệ dòng quá tải, bộ bảo vệ nhiệt độ chống đông, bộ bảo vệ dòng nước, công tắc dừng khẩn cấp, bu lông dễ nóng chảy nhạy cảm với nhiệt độ, van an toàn, v.v. .

Nó được công nhận là thành phần cấu trúc lý tưởng nhất của máy chủ làm lạnh trung tâm.

6.

Loại ống titan chống ăn mòn:

Thiết bị bay hơi titan đặc biệt có thể tránh ăn mòn chất lỏng axit và có thể đóng băng trực tiếp mạ điện, chất lỏng oxy hóa, nước biển, nước muối và các chất lỏng ăn mòn khác.

Đặc điểm và ưu điểm của các loại máy làm lạnh Đọc thêm »

Chuẩn bị trước khi lắp đặt máy làm lạnh nước

Find it hard or complicate to install a water chiller? Don’t know how to pick up a right place to settle your new water chiller?

Actually , you just need to do below steps one by one.Then everything will become very simple.

Let’s do it!

Check the components are complete

Before installation, check whether the components of the unit are complete.

The Right Cooling water tower and Cooling water pump

Select the appropriate cooling tower (air cooling type does not need cooling tower), and the capacity of cooling water pump should match the model. Please install according to the size of the body pipe, do not reduce the size of the cooling pipe, in order to avoid causing high pressure overload, affecting the cooling effect and increasing power consumption.

Correct handling methods

Correct handling method: use stacker, crane and drum. Do not drag the machine by force. Since the equipment has been debugged before leaving the factory, the system has pressure, so strong vibration is not allowed during loading and unloading, handling and installation. It is not allowed to invert, tilt or side set the unit during handling.

The right installation location requested:

The water chiller is an indoor device. If the user needs to place the equipment outdoors, it should be well protected from rain and sun, and should not be directly exposed to the outside.

 

The installation location should be a place with stable foundation, open surroundings, ventilation, avoiding corrosion and pollution, and convenient for installation and maintenance.

Since the unit itself will generate heat, it is necessary to avoid high temperature area around the unit during installation to meet the effective heat dissipation of the equipment, especially to ensure that the condenser of air-cooled chiller is well ventilated.

Avoid placing high-power inverter, welding machine and other equipment with interference sources near the equipment, and the installation space of the unit shall not be less than the size shown in the figure below. The figure shows the minimum installation space of the unit (unit: mm).

Water-cooled water chiller (Box type or Open type)
Air-cooled water chiller

The unit without caster at the bottom

The unit without caster at the bottom must be placed on the horizontal concrete base, and there must be no less than 3mm thick damping rubber pad between the unit and the concrete base

It is better to install large air-cooled units in outdoor space.

On the other hand, it can reduce heat emission. When placing, please support the bottom of the unit with bracket to make it ventilate smoothly and prevent rusting.

Note:

(1) the power load and grounding part shall be constructed in accordance with relevant laws and regulations

(2) The chilled water pipes of newly installed chillers must be covered with insulation layer.

Chuẩn bị trước khi lắp đặt máy làm lạnh nước Đọc thêm »

Ứng dụng của thiết bị làm lạnh công nghiệp APT

Ứng dụng công nghệ điện lạnh năm 2021

With the development of refrigeration industry, the application of refrigeration technology is becoming more and more extensive. Now it has penetrated into all fields of people’s life and production activities, from daily clothing, food, housing, transportation, to cutting-edge science and technology can not do without refrigeration technology.

1. Food Engineering

 

In order to prolong and improve the quality, economic life and value of perishable food, it is necessary to maintain a stable low temperature environment in the whole circulation process of perishable food from purchase or fishing, processing, storage, transportation to sales. This requires a variety of refrigeration facilities, such as cold processing equipment, refrigerated warehouses, refrigerated transport vehicles or ships, refrigerated sales counters and so on.

 

2. Air conditioning engineering

Air conditioning engineering is a wide application field of refrigeration technology. The temperature, humidity and cleanliness of the environment are required to be controlled in different degrees in optical instruments, precision measuring tools, textile workshops and computer rooms; comfortable air conditioning systems are also required for public buildings such as gymnasiums, great halls, hotels and other public buildings, cars, airplanes, and large buses.

3. Mechanical and electronic industry

Máy làm lạnh nước công nghiệp 20HP

 

Precision machine tool oil pressure system uses refrigeration to control the oil temperature, which can stabilize the oil film stiffness and make the machine work normally. Low temperature treatment of steel can improve the properties of steel, improve the hardness and strength of steel, and prolong the service life of workpiece. Multi channel communication, radar, satellite ground station and other electronic equipment also need to work in low temperature.

 

Swimming pool water chiller 1HP-3HP

Plasma, vaccines and some special drugs need to be preserved at low temperature. Low temperature anesthesia, low temperature surgery and cold compress cooling of patients with high fever also need refrigeration technology.

4. National defense industry and modern science

It is also necessary to simulate the performance

of these weapons and vehicles in the cold environment. Artificial rainfall also needs cooling.

Ứng dụng công nghệ điện lạnh năm 2021 Đọc thêm »

Cảm ơn !

Tin nhắn đã được gửi thành công.

Chúng tôi sẽ liên hệ với bạn trong vòng 1 ngày làm việc. Vui lòng chú ý đến email có hậu tố “@topwaterchiller.com”.

Hy vọng chúng ta có mối quan hệ bsiness ổn định trong tương lai.